Wincc 7.5 Sp2 Compatibility List -

SIMATIC WinCC V7.5 SP2 is compatible with several 64-bit Windows operating systems, including Windows 10, Windows 11 (with specific updates), and multiple Windows Server versions. Operating System Compatibility

WinCC V7.5 SP2 supports the following 64-bit operating systems: Windows 10: Professional and Enterprise. Windows 10 LTSC: LTSB 2015/2016 and LTSC 2019.

Windows 11: Supported starting from WinCC V7.5 SP2 (typically requiring the latest updates/service packs for full official support, such as Pro version 21H2). Windows Server 2012 R2: Standard and Datacenter editions. Windows Server 2016: Standard and Datacenter editions. Windows Server 2019: Standard and Datacenter editions.

Windows Server 2022: Successfully reported as compatible in community environments. Software & Hardware Requirements Delivery Release SIMATIC WinCC V7.5 SP2 including options

SIMATIC WinCC V7.5 SP2 is a versatile HMI/SCADA software release that serves as a bridge for modern Windows environments, notably being the first version in the V7 series to support Windows 11 and Windows Server 2022. This update is essential for users moving away from older hardware while maintaining the specialized architecture of the WinCC V7 line. Key Compatibility Overview WinCC 7.5 Windows 11 - SiePortal - Siemens

SIMATIC WinCC V7.5 SP2 is a widely used SCADA system designed for complex plant visualizations. According to the official Siemens release notes, compatibility centers on specific 64-bit operating systems and database versions. Operating System Compatibility

WinCC V7.5 SP2 is officially supported on the following 64-bit platforms: Windows 10: Professional and Enterprise. Windows 10 Enterprise LTSC: 2015, 2016, and 2019 versions.

Windows 11: Supported as of version 22H2 (Pro and Enterprise) and later, though specific Windows 11 releases like 25H2 may not yet be approved. Windows Server: Windows Server 2012 R2. Windows Server 2016. Windows Server 2019. Database & Software Requirements

Microsoft SQL Server: Requires SQL Server 2016 SP2 (64-bit) in either Standard or Express editions.

Internet Explorer: For internal web components on Windows 11, Internet Explorer 11 must be enabled via Windows Features.

Exclusions: It cannot be installed simultaneously with WinCC RT Professional (TIA Portal), WinCC Unified, or legacy WinCC V6/V7.x versions. Compatible Options & Components

The following Siemens add-ons and options are released for use with V7.5 SP2: Communication: SIMATIC Net V16.

Web Systems: WinCC/WebNavigator V7.5 SP2 and WinCC/WebUX V7.5 SP2.

Reporting & Archiving: SIMATIC Information Server 2014 SP3 (Upd4/5) and SIMATIC Process Historian 2014 SP3.

Standard Options: Server, Redundancy, UserArchives, Connectivity Pack, and DataMonitor (all V7.5 SP2).

For the most up-to-date and specific hardware/firmware combinations, users should utilize the Siemens Compatibility Tool to verify their exact configuration.

Are you planning to upgrade an existing system or perform a fresh installation on new hardware?

WinCC V7.5 SP2 Architectures - Digital Asset Management - Siemens

The significance of the WinCC 7.5 SP2 compatibility list extends far beyond a mere technical datasheet; it represents the critical bridge between legacy industrial stability and modern computing environments. In the complex world of Supervisory Control and Data Acquisition (SCADA), software compatibility is the foundation upon which operational reliability is built. For engineers and system integrators, the release of Service Pack 2 for SIMATIC WinCC 7.5 marked a pivotal moment in the lifecycle of the product, specifically regarding its alignment with the evolving Windows ecosystem.

A primary pillar of the WinCC 7.5 SP2 compatibility framework is its relationship with operating systems. While earlier iterations of the 7.5 series were anchored to older environments, WinCC 7.5 SP2 (or 8.0) is compatible with Windows 11, effectively extending the relevant lifespan of existing hardware and software investments. This compatibility also includes support for Windows Server 2022, providing a robust path for enterprises to modernize their server infrastructure without abandoning a stable SCADA platform. The strict adherence to these released combinations is non-negotiable for maintaining manufacturer support and ensuring system integrity.

Beyond the operating system, the compatibility list serves as a roadmap for integration within the broader Siemens automation portfolio. In industrial settings, WinCC rarely operates in a vacuum; it must coexist with engineering tools like the TIA Portal and SIMATIC STEP 7. The compatibility documentation ensures that communication drivers, database interfaces, and optional packages—such as WinCC/WebNavigator or WinCC/Audit—are synchronized with the core Service Pack 2 updates. This synchronization prevents the "version mismatch" errors that can cripple a facility during a staged upgrade.

Furthermore, the transition to WinCC 7.5 SP2 highlights the evolution of system architectures. While WinCC Professional is often associated with the TIA Portal ecosystem, WinCC v7.5 supports a Distributed architecture, allowing for up to 18 redundant servers. Understanding how SP2 impacts these distributed environments is essential for high-availability applications where downtime is not an option.

Ultimately, the WinCC 7.5 SP2 compatibility list is an essential risk-management tool. It allows decision-makers to plan upgrades with precision, identifying exactly which hardware needs replacement and which virtual environments are suitable for hosting. By consulting the Siemens Compatibility Tool for these specific releases, organizations can navigate the shift toward modern IT standards while preserving the proven logic and visualization of their industrial processes. wincc 7.5 sp2 compatibility list

To help you narrow down the specific details you need, please let me know:

Are you checking compatibility for a specific Operating System (e.g., Windows 10 LTSC vs. Windows 11)?

Do you need to verify integration with other software like TIA Portal or STEP 7?

Are you planning a fresh installation or an upgrade from an older version? WinCC 7.5 Windows 11 - SiePortal - Siemens

Navigating WinCC 7.5 SP2: The Essential Compatibility Guide Upgrading your SCADA system often feels like a high-stakes puzzle. For those working with SIMATIC WinCC V7.5 SP2, ensuring your operating system and secondary software are perfectly aligned is the difference between a smooth deployment and a troubleshooting nightmare.

The primary rule for any Siemens installation is to use the Official Siemens Compatibility Tool for real-time verification. However, here is a consolidated look at the core compatibility requirements you need to know. Operating System Support

WinCC 7.5 SP2 is a versatile release, offering support for both modern workstations and established server environments. Notably, this version (or newer) is required for compatibility with Windows 11. Workstations (64-bit only): Windows 10 Professional & Enterprise Windows 10 LTSB 2015/2016 and LTSC 2019/2021 Windows 11 Professional & Enterprise Servers (64-bit only): Windows Server 2012 R2 Windows Server 2016 Windows Server 2019 Windows Server 2022 Critical Software & Databases

WinCC relies heavily on its database engine and communication drivers. Misalignment here is the most common cause of installation failure. WinCC 7.5 Windows 11 - SiePortal - Siemens

SIMATIC WinCC V7.5 SP2 is compatible with modern 64-bit Windows operating systems, including Windows 11 as of specific updates. To ensure a stable installation, you must use the official Siemens Compatibility Tool for the most current validated combinations. Operating System Compatibility

The following 64-bit operating systems are officially supported for WinCC V7.5 SP2:

Windows 11: Supported beginning with version 22H2. Note that Internet Explorer 11 must be enabled via Windows Features for internal web components to function.

Windows 10: Professional and Enterprise (versions 2004, 20H2). Windows 10 LTSC: LTSB/LTSC 2016 and LTSC 2019. Windows Server: Windows Server 2012 R2 (Standard/Datacenter). Windows Server 2016 (Standard/Datacenter). Windows Server 2019 (Standard/Datacenter). Windows Server 2022 (verified by community installations). Software Prerequisites

.NET Framework: Must be enabled prior to installation. Windows 10/Server 2016 requires version 4.7, while Server 2012 R2 requires 4.6.1.

Microsoft SQL Server: WinCC V7.5 SP2 typically bundles SQL Server 2016 SP2 (64-bit). If you need to use SQL Server Express, it must be installed before WinCC as a named instance to avoid conflicts.

Microsoft Office: Compatible with Office 365 Professional Plus (32/64-bit) version 1908. Virtualization & Maintenance

Virtualization: Often deployed using VMware environments for "world without UCL" (Unified Compatibility List) architectures.

Updates: It is highly recommended to install the latest updates (e.g., Update 7 or higher) to ensure compatibility with Windows 11 and newer Microsoft components.

For detailed technical manuals and release notes, you can refer to the Siemens Industry Online Support (SIOS) portal. 5 SP2 server or client installation? WinCC V7.5 SP2 Architectures - Siemens

Compatibility List for WinCC 7.5 SP2

WinCC 7.5 SP2, a Supervisory Control and Data Acquisition (SCADA) system developed by Siemens, is widely used in various industries for monitoring, controlling, and managing complex systems. To ensure seamless integration and operation, it is crucial to verify the compatibility of WinCC 7.5 SP2 with other software and hardware components. This essay provides an overview of the compatibility list for WinCC 7.5 SP2, highlighting its supported operating systems, databases, and other relevant software.

Operating Systems

WinCC 7.5 SP2 supports the following operating systems: SIMATIC WinCC V7

It is essential to note that WinCC 7.5 SP2 is not compatible with 32-bit operating systems.

Databases

WinCC 7.5 SP2 supports the following databases:

Other Software

WinCC 7.5 SP2 is compatible with the following software:

Hardware

WinCC 7.5 SP2 supports a wide range of hardware devices, including:

Compatibility Considerations

When planning to install or upgrade to WinCC 7.5 SP2, it is crucial to consider the compatibility of existing software and hardware components. Incompatible components may lead to system crashes, data loss, or other issues. Therefore, it is recommended to:

In conclusion, WinCC 7.5 SP2 is a powerful SCADA system that requires careful planning and compatibility verification to ensure smooth operation. By understanding the compatibility list and considering the specific requirements of your system, you can ensure a successful implementation and minimize potential issues.

SIMATIC WinCC 7.5 SP2 is a major service pack that significantly expands operating system support, including initial official compatibility for Windows 11 and Windows Server 2022

. To verify specific combinations not listed here, use the official Siemens Compatibility Tool Operating System Compatibility

WinCC 7.5 SP2 is compatible with 64-bit versions of the following operating systems: Windows 10 : Professional and Enterprise. Windows 10 LTSC : LTSB 2015/2016 and LTSC 2019. Windows 11

: Pro and Enterprise (supported from WinCC 7.5 SP2 onwards). Windows Server 2012 R2 : Standard/Datacenter. Windows Server 2016/2019 : Standard/Datacenter. Windows Server 2022 : Standard/Datacenter. Software & Engineering Tool Compatibility : Compatible with STEP 7 V5.6 HFx/SP2 for integrated operation in SIMATIC Manager. SIMATIC Net : Supports SIMATIC Net V16 and later. Historian & Information Server : Compatible with Process Historian 2014 SP3 Upd4/5 Information Server 2014 SP3 Upd4/5 PM-Products

: Various versions of PM-ANALYZE (e.g., v7.5 and higher) are tested for compatibility with WinCC 7.5 SP2. Tested Virus Scanners

Siemens officially lists the following antivirus suites as compatible:

: Endpoint Protection Suite V10.5 and VirusScan Enterprise V8.8. Trend Micro : OfficeScan V12.0 SP1. : Endpoint Protection V14.3. : Endpoint Security for Windows 2018. Important Version Notes SQL Server : WinCC 7.5 SP2 uses SQL Server 2016 SP2 (64-bit)

. Attempting to install the base WinCC 7.5 (non-SP) on Windows 11 often fails because the older SQL version included is not supported by that OS. Installation Tip

: For the most stable experience on modern OS versions like Windows 11, it is recommended to use the WinCC V7.5 SP2 full installation medium rather than upgrading from 7.5 base. : It is highly recommended to install the latest WinCC 7.5 SP2 Updates

to fix known issues, such as alarm acknowledgment bugs found in earlier updates like Update 10. Are you planning to perform a fresh installation on Windows 11, or are you an existing WinCC 7.5 project? WinCC V7.5 SP2 Architectures - Siemens

The compatibility of SIMATIC WinCC V7.5 SP2 is a critical factor for industrial SCADA deployments

, as this version serves as a bridge for legacy systems moving toward modern operating environments like Windows 11. Operating System Support Windows 10 (64-bit), version 1709, 1803, 1809, and

WinCC V7.5 SP2 is officially released for the following 64-bit operating systems: Windows 10 : Professional and Enterprise. Windows 10 LTSC : LTSB 2015/2016, LTSC 2019, and LTSC 2021. Windows 11

: Professional and Enterprise (requires WinCC V7.5 SP2 as the minimum version). Windows Server Server 2012 R2 Server 2016 Server 2019 Server 2022 Software Integration & Security

For seamless operation within the SIMATIC ecosystem, WinCC V7.5 SP2 is compatible with several key engineering and communication tools: Engineering : Compatible with STEP 7 V5.6 HFx/SP2 for integrated operation in SIMATIC Manager. Communication : Designed for industrial communication with SIMATIC NET V16 : Tested and approved for use with McAfee Endpoint Protection Trend Micro OfficeScan (V12.0 SP1), Symantec Endpoint Protection (V14.3), and Kaspersky Endpoint Security Virtualization Solutions

WinCC V7.5 SP2 supports server-based virtualization, which is common in modern data centers: Microsoft Hyper-V : Versions 2012 R2 and 2016. VMware ESXi : Versions 6.5 and 6.7. Remote Access : For distributed plants,

is the recommended software for remote access to WinCC Servers. Critical Technical Notes SQL Server

: Standard WinCC 7.5 may fail on Windows 11 due to SQL Server 2016 restrictions; is required to resolve these compatibility issues. Coexistence : WinCC V7.5 SP2

be installed on the same machine as WinCC Runtime Professional (TIA Portal), WinCC Unified, or older V6/V7 versions. Secure Communication

: For connections to S7-1500 (V2.9+) or S7-1200 (V4.5+) controllers, specific updates (Update 4 or higher) are required to handle "Secure Communication" protocols.

For the most up-to-date and specific configuration checks, users should consult the official Siemens Compatibility Tool licensing options for this version? WinCC 7.5 Windows 11 - SiePortal


Real-World Issues to Watch For

  1. Windows Updates – Certain security patches can break WinCC services. Always test updates in a VM first.
  2. Multi-monitor setups – Works fine, but screen cycles may lag on older GPUs.
  3. Remote desktop – Allowed for configuration, not for runtime operation.

4. Hardware and Automation Compatibility (PLC Communication)

WinCC 7.5 SP2 communicates primarily via SIMATIC NET and native drivers. Here is the compatibility list for common controllers:

| Controller Family | Required Driver | Compatibility Status | Notes | | :--- | :--- | :--- | :--- | | S7-1500 | S7-1500 channel (native) | ✅ Fully compatible | Supports optimized DB blocks | | S7-1200 | S7-1200 channel | ✅ Fully compatible | Firmware v4.0 to v4.5 tested | | S7-300 / S7-400 | Industrial Ethernet (ISO-on-TCP) | ✅ Fully compatible | Legacy support unchanged from WinCC 7.5 SP1 | | S7-200 (PPI/MPI) | Logical driver via PC Adapter | ⚠️ Limited | Requires legacy USB-MPI adapter; no Windows 10 driver for old PPI. Use a gateway. | | SINUMERIK CNC | SINUMERIK NC Connect | ✅ Compatible via dedicated package | Requires separate license | | OPC UA (Client/Server) | OPC UA WinCC Channel | ✅ Fully compatible | Supports DA, HA, and AC (PubSub limited) |

Licensing in VMs:

Soft dongles (ALM) are difficult to manage in dynamic VMs. Siemens recommends using a USB hardware dongle on a dedicated key server or Static license file (SLS).


6. Antivirus and Security Software Compatibility

WinCC 7.5 SP2 is sensitive to real-time scanning of its archive and project folders.

| Software | Compatibility Status | Required Configuration | | :--- | :--- | :--- | | Symantec Endpoint Protection | ✅ Compatible | Exclude folders: C:\Program Files\Siemens\, C:\WinCC\, *.mdf, *.ldf | | McAfee VirusScan | ⚠️ Degraded performance | Must disable "On-access scan" for WinCC services | | Windows Defender | ✅ Compatible (Win10 LTSC) | Add exclusions via PowerShell (Set-MpPreference -ExclusionPath) | | Trend Micro | ❌ Not recommended | Known to block SQL replication between redundant servers |

What about SIMATIC Logon?

SIMATIC Logon 1.6 SP3 is fully compatible. Do not use v1.7 (for TIA Portal V17) – it will break WinCC user administration.

The Ultimate Guide to WinCC 7.5 SP2 Compatibility List: OS, SQL, and Hardware

SIMATIC WinCC (Windows Control Center) is Siemens’ flagship SCADA (Supervisory Control and Data Acquisition) system. With the release of WinCC V7.5 SP2, Siemens introduced significant improvements, including enhanced performance, better integration with the TIA Portal (via shared data access), and support for modern IT security standards.

However, before upgrading or deploying a new project, the single most critical document you need is the WinCC 7.5 SP2 compatibility list. Installing this version on an unsupported operating system or with the wrong SQL server is a recipe for runtime errors, system crashes, or silent data corruption.

This article provides a detailed breakdown of the official compatibility matrix for WinCC 7.5 SP2, covering operating systems, SQL versions, automation hardware, and office integrations.


1. Operating System Compatibility

WinCC V7.5 SP2 is compatible with the following Windows operating systems (64-bit versions are standard for WinCC 7.x):

| Operating System | Support Status | | :--- | :--- | | Windows 10 | Supported.
Specifically: Version 1607, 1803, 1809, 1903, 1909, 2004, 20H2, 21H2.
(Note: Windows 11 is not supported by V7.5 SP2; you need WinCC V7.5 SP3 or higher for Win11). | | Windows Server | Supported.
Specifically: Windows Server 2016 and Windows Server 2019. | | Windows 7 | Not Supported.
WinCC 7.5 SP2 requires Windows 10 or Server 2016/2019. |

Important Note: Always check the specific "Readme" file or release notes for the exact OS Build numbers (KB patches). Some Windows Updates released after the SP2 release may require a specific WinCC Update patch to maintain compatibility.