Introduction
- The Urmet 1131 is a door entry system that allows residents to communicate with visitors and grant access remotely.
- This manual provides a detailed guide on how to install, configure, and use the Urmet 1131 system.
System Components
- The Urmet 1131 system consists of the following components:
- Main unit (1131/1)
- Power supply unit (PSU)
- Door release unit
- Electric lock
- Monitor (optional)
- Microphone and speaker
Installation
- Main Unit Installation
- Mount the main unit on a wall or in a cabinet
- Connect the power supply unit to the main unit
- Connect the door release unit to the main unit
- Connect the electric lock to the door release unit
- Power Supply Unit Installation
- Mount the power supply unit in a suitable location
- Connect the power supply unit to the main unit
- Connect the power supply unit to the electrical network
- Door Release Unit Installation
- Mount the door release unit near the door
- Connect the door release unit to the main unit
- Connect the electric lock to the door release unit
- Electric Lock Installation
- Install the electric lock on the door
- Connect the electric lock to the door release unit
Configuration
- Programming the System
- Use the programming menu to configure the system
- Set the system parameters (e.g., language, date and time, etc.)
- Configure the door release and electric lock settings
- Setting Up the Monitor (Optional)
- Connect the monitor to the main unit
- Configure the monitor settings (e.g., brightness, contrast, etc.)
Operation
- Receiving Calls
- When a visitor presses the call button, the system rings and displays the visitor's image (if a monitor is connected)
- Answer the call by pressing the answer button
- Communication
- Communicate with the visitor through the microphone and speaker
- Press the door release button to grant access to the visitor
- Door Release
- The door release unit activates the electric lock to unlock the door
- The door release time can be adjusted through the programming menu
Additional Features
- Night Mode
- The system can be set to night mode, which reduces the volume and adjusts the display settings
- Volume Control
- Adjust the volume of the microphone and speaker through the programming menu
- Event Log
- The system records events, such as calls, door releases, and system errors
Troubleshooting
- Error Messages
- The system displays error messages for system errors or malfunctions
- Refer to the troubleshooting guide for solutions to common issues
- System Reset
- Reset the system to its default settings
Technical Specifications
- Main Unit
- Dimensions: 210 x 150 x 50 mm
- Weight: 1.5 kg
- Power consumption: 10W
- Power Supply Unit
- Input voltage: 230VAC
- Output voltage: 12VDC
- Power consumption: 20W
- Door Release Unit
- Output voltage: 12VDC
- Current capacity: 2A
Warranty and Maintenance
- Warranty
- The Urmet 1131 system has a 2-year warranty
- Contact the manufacturer for warranty claims and repairs
- Maintenance
- Regularly clean and inspect the system to ensure proper operation
- Perform software updates as necessary
Urmét 1131 Manual: A Comprehensive Guide
Introduction
The Urmét 1131 is a popular intercom system used in various settings, including residential, commercial, and industrial environments. This manual aims to provide a comprehensive guide for users, installers, and maintainers of the Urmét 1131 system. In this piece, we will cover the features, installation, operation, and troubleshooting of the Urmét 1131.
Features of Urmét 1131
The Urmét 1131 is a versatile intercom system that offers a range of features, including:
- Audio and Video Communication: The system allows for clear audio and video communication between the main unit and remote stations.
- Multiple Door Stations: The Urmét 1131 supports multiple door stations, allowing for communication with various points of entry.
- Hands-Free Operation: The system features hands-free operation, making it easy to communicate without having to press buttons.
- Call Transfer: The Urmét 1131 allows for call transfer between door stations and internal stations.
Installation
Installing the Urmét 1131 requires careful planning and attention to detail. The following steps outline the installation process:
- Mounting the Main Unit: The main unit should be mounted in a secure location, such as a reception area or security room.
- Connecting Door Stations: Door stations should be connected to the main unit using a 4-wire cable.
- Installing Remote Stations: Remote stations should be installed in areas where communication with the main unit is required.
- Powering the System: The system should be powered using a 12V DC power supply.
Operation
Operating the Urmét 1131 is straightforward. The following steps outline the basic operation:
- Making a Call: To make a call, simply lift the handset or press the call button on the door station.
- Answering a Call: To answer a call, lift the handset or press the answer button on the main unit.
- Call Transfer: To transfer a call, press the transfer button on the main unit and select the desired station.
Troubleshooting
Troubleshooting the Urmét 1131 requires a systematic approach. The following steps outline common issues and solutions:
- No Audio or Video: Check the power supply, cable connections, and door station settings.
- Distorted Audio: Check the audio settings, cable connections, and door station settings.
- No Call Transfer: Check the call transfer settings, cable connections, and station settings.
Technical Specifications
The Urmét 1131 has the following technical specifications: urmet 1131 manual full
- Frequency Response: 50 Hz - 20 kHz
- Audio Output: 1W
- Video Output: 1Vp-p
- Operating Temperature: -10°C - 50°C
- Humidity: 20% - 80%
Conclusion
The Urmét 1131 is a reliable and versatile intercom system that offers a range of features and benefits. By following this manual, users, installers, and maintainers can ensure optimal performance and troubleshoot common issues. For further assistance, please consult the manufacturer's website or contact a authorized dealer.
Appendix
The following diagrams and illustrations are provided to aid in the installation and operation of the Urmét 1131:
- System Diagram: A diagram showing the main unit, door stations, and remote stations.
- Wiring Diagram: A diagram showing the wiring connections between the main unit, door stations, and remote stations.
- Installation Drawing: A drawing showing the recommended installation layout.
By following this comprehensive guide, users can ensure optimal performance and get the most out of their Urmét 1131 intercom system.
The Urmet 1131 system is part of the Urmet 2Voice (or similar) wired video door entry range. A "full manual" typically includes three distinct documents: System Technical Manual (for installers), User Manual (for residents), and Programming Manual.
Since I cannot directly attach PDF files, here is how to get the complete official manual and a summary of the critical technical sections you are likely looking for. Introduction
3. Installation Guide
5. Programming (Basic Draft Instructions)
4. Installation Instructions
7. Maintenance
- Clean handset/monitor surface with a soft damp cloth; avoid solvents.
- Periodically check terminals for corrosion and tighten loose connections.
- Test door-release and call functions monthly.
4. Physical Connections (Typical)
| Terminal | Signal |
|----------|--------|
| L1 / L2 | 2-wire BUS (to Urmet riser / power supply) |
| TEL LINE | Incoming PSTN line (from Telecom socket) |
| TEL SET | Optional parallel telephone |
| NO / C / NC | Relay 1 (e.g., electric lock) |
| NO2 / C2 / NC2 | Relay 2 (e.g., auxiliary) |
| +12V / GND | Optional external power (if not powered via BUS) |
4.3 Low Voltage Wiring (Output)
The output terminals provide the DC voltage for the system devices.
- Identify the
+ (Positive) and - (Negative) output terminals.
- Use appropriate gauge cable (e.g., 0.5mm² to 1.5mm²) depending on the distance of the cable run to prevent voltage drop.
- Connect the positive wire from the load (e.g., Electric Strike, Intercom Monitor) to the
+ terminal.
- Connect the negative wire to the
- terminal.
Report: Urmet 1131 Manual — Full Overview
Step 3: Connections
- Video: Connect the coaxial cable to the BNC connector on the camera pigtail.
- Power: Connect the 12V DC power supply to the power terminal (usually a screw terminal or DC jack). Caution: Ensure the polarity is correct (Positive to Positive, Negative to Negative) to avoid damaging the unit.