Orona Arca II Test Tool (also known as a Maintenance Terminal or Configuration Tool) is an essential diagnostic device used for the commissioning, maintenance, and troubleshooting of Orona lift systems, specifically those utilizing the controllers. Core Technical Overview Primary Function
: Enables technical personnel to interact with the elevator controller to read system statuses, modify operational parameters, and identify specific hardware or software faults. Connectivity : The tool typically connects directly to the
(main CPU board) or the cabin's ceiling plate (PDCC) in ARCA II models. User Interface
: Features a display screen and navigation keypad to scroll through hierarchical menus. Essential Operations & Functions technical manuals , the tool is categorized into specific diagnostic menus: Maintenance Terminal Manual ORONA ARCA 2 | PDF - Scribd
The Orona Arca 2 Test Tool (often referred to as the Configuration Tool or Service Tool) is a handheld diagnostic device used by technicians to interact with Orona Arca I and Arca II elevator controllers. It allows for real-time monitoring, parameter adjustment, and fault diagnostics. 1. Getting Started To begin using the tool, follow these initial steps:
Connection: Plug the Configuration Tool connector into the dedicated service port on the Arca II control board. Note that Arca II control plates typically use female connectors, while the service tool has a male connector.
Power On: Once connected, the screen should display "ORONA (C)". Press any key to enter the main interface.
Authentication: You may be prompted for a password. Use the keypad to enter the code; a blinking cursor will indicate where to type. 2. Navigation & Interface
The tool operates similarly to other industry-standard terminals, such as those from Otis.
Menu Navigation: Use the arrow or dedicated directional keys to move the cursor through the menu tree.
Selection: Position the cursor on the desired function and press the enter/action key to select it.
Editing Values: To change a parameter (like speed or timers), navigate to the specific parameter and follow the on-screen prompts to input new numerical values. 3. Core Menu Functions orona arca 2 test tool top
The Arca II test tool organizes its functions into several top-level categories:
Status Monitoring (Present): Displays real-time data such as car position, current floor, door status, and safety chain continuity.
CT Functions (Configuration): Used for setting up the installation, including device configuration and system-wide parameters like travel speeds.
Fault Diagnosis: Accesses the "fault stack" stored on the CPU board. This section lists active and historical error codes (e.g., safety chain interruptions or communication errors). Maintenance Functions: Includes specialized tests such as:
Gap Learning: Re-calibrates the floor positions and shaft signals.
Time/Date Adjustments: Modifies the controller's internal clock for accurate fault logging.
I/O Testing: Verifies inputs and outputs for remote stations and cabin roof extensions. 4. Safety & Troubleshooting
Safety Chain: The tool is vital for identifying where a safety circuit is broken (e.g., point 32 for travel contacts or point 35 for landing doors).
Resetting Faults: While the Arca II has non-volatile memory for faults, the tool can be used to clear the stack after repairs are completed.
Hardware Repair: If your tool is malfunctioning, specialized electronics services like Nintec Electronics offer repair and verification on test rigs. Maintenance Terminal Manual ORONA ARCA 2 | PDF - Scribd
The Orona Arca II Test Tool is the primary diagnostic and configuration device used by technicians to service elevators equipped with Orona Arca I and Arca II controllers Orona Arca II Test Tool (also known as
Often referred to in the industry as a "Service Tool" or the "RT-1 Tool," this handheld device acts as the brain-to-technician interface. It allows maintenance personnel to read system faults, adjust operational parameters, and ensure that the elevator runs safely and efficiently.
Below is a comprehensive guide to understanding the functions, importance, and operation of the Orona Arca II Test Tool. Key Functions of the Arca II Test Tool
Modern traction and hydraulic elevators rely on complex computer boards. When a component fails or requires calibration, looking at the hardware alone is rarely enough. The Arca II test tool provides the following critical capabilities: Alibaba.com Real-Time Fault Diagnostics:
Technicians can view active error codes and historical fault logs to pinpoint exactly why an elevator has shut down or is acting erratically. Parameter Configuration:
It allows authorized personnel to set floor levels, adjust door opening/closing speeds, and calibrate weight-sensing systems. System Monitoring:
The tool reads live data from the control cabinet, including car position, active safety circuit nodes, and motor drive outputs. Maintenance & Setup Commands:
Technicians can command the lift to perform specific test runs, override certain calls during maintenance, or perform a complete system reboot. Technical Specifications and Compatibility Compatible Systems Orona Arca I and Arca II Controllers Common Model Names RT-1 Tool, Arca Service Tool LCD screen with a tactile navigation keypad Connectivity
Proprietary multi-pin connector plug directly to the main CPU board Language Support Available in multiple localized versions, including English How to Use the Orona Arca II Test Tool
While specific procedures vary based on the exact software version and repair operation, the standard workflow for using the tool follows these steps: Repair of Orona Arca II test tool - Nintec Electronics
1. Equipment Identification
2. The "Test Tool Top" Context In the context of elevator maintenance, "Top" usually refers to a Top-of-Car Inspection or a specific Top Floor Limit Test. Technical Overview: Orona ARCA 2 Test Tool 1
Top-of-Car Inspection Mode: The ARCA 2 unit facilitates the "Inspection" mode required by safety standards (EN 81). When a technician is on top of the car, the ARCA 2 interface is used to move the elevator at inspection speed (usually slow speed) to check guide rails, door locks, and clearance at the top floor.
Top Floor Terminal Switch Testing: A critical function of the ARCA 2 tool is testing the Final Limit Switches (Top and Bottom).
3. Key Features of the ARCA 2 Tool
4. Safety Standards (The "Solid Paper" Aspect) If you are writing a report or safety paper, you should reference the harmonized standards that dictate how the "Test Tool" operates:
Live data streaming lets you monitor:
While a basic Arca 2 tester exists, the Top version includes:
The Arca 2 Test Tool Top is a portable, handheld diagnostic device specifically designed for Orona’s Arca 2 series of hydraulic and traction elevator systems. Unlike generic multimeters or basic diagnostic tools, this unit plugs directly into the elevator’s control board, providing real-time data, fault logging, and component activation.
The “Top” designation typically refers to the advanced or full-featured version of the tool, offering expanded memory and access to proprietary system parameters.
The Orona Arca 2 Test Tool Top is typically sold through Orona’s official distributor network or authorized elevator parts suppliers. As of 2025, pricing ranges from €1,200 to €2,000 depending on region and bundled software licenses.
If the official tool is unavailable, third-party CAN bus analyzers might read some data, but they lack the proprietary protocol decoding and component override functions. For serious Orona maintenance, the Arca 2 Test Tool Top remains the gold standard.
The tool instantly retrieves active and historical fault codes from the elevator controller. Each code is displayed with plain-text descriptions (or coded references), allowing technicians to pinpoint issues ranging from door interlock failures to inverter overloads without guesswork.