The process for updating the FNIRSI-1014D firmware involves placing a specifically named binary file onto the device's internal storage via USB and restarting the unit to trigger an automatic installation. As of early 2026, the latest known official stable release remains Version 3.0. Firmware Update Procedure

Preparation: Download the firmware file, typically named FSI-1014.bin, from the FNIRSI Official Support Page.

Connection: Connect the oscilloscope to a PC using a USB data cable.

USB Export Mode: Open the oscilloscope's MENU and select USB export. The device will appear on your computer as a removable 8GB drive. File Transfer:

Remove existing files from the new drive to ensure a clean install. Copy the FSI-1014.bin file to the root of the drive.

Crucial: Safely "eject" or "unmount" the drive from your PC before disconnecting the cable.

Installation: Power off the oscilloscope, then power it back on. The device will detect the file, display a progress bar for roughly 20 seconds, and reboot automatically once complete. Critical Risks & Troubleshooting

Screen Shift Error: There are two variants of Version 3.0 firmware because FNIRSI used two different screen types during production. If your display appears shifted or parameters are cut off after an update, you must re-flash with the alternate Version 3.0 file.

Failed Boot/White Screen: If the device fails to boot or displays a blank screen, you may need to format the internal microSD card (FAT32) and reload the support files manually.

Custom Firmware: Community-driven reverse engineering projects on GitHub offer open-source alternatives that include custom bootloaders for multi-firmware booting. Summary of Latest Firmware (As of April 2026) Release Date V3.0

Standard latest stable; two variants exist for different displays. Custom

Community-made bootloaders allowing multiple firmware options. FNIRSI 1014D - How to do a Firmaware Upgrade Tutorial

The FNIRSI-1014D is a beloved but quirky piece of hardware—a dual-channel oscilloscope known for its responsive touchscreen and high refresh rate, but infamous for its questionable measurement accuracy out of the box. For electronics enthusiasts, it is the ultimate "fixer-upper."

This is the story of one engineer’s quest to unlock the machine's true potential through a firmware update.


After the update

If you want, I can:

The FNIRSI 1014D firmware update is a manual process that involves transferring a .bin file to the device's internal storage via a PC connection. While the official process is straightforward, users frequently encounter hardware-specific issues like screen misalignment, which may require specific versions of the firmware. 1. Official Update Process To update the FNIRSI 1014D, follow these standard steps: fnirsi1014d firmware update work

Download: Get the latest firmware (currently V3.0) from the FNIRSI Software Center.

Connect: Power on the unit and connect it to a PC using a USB data cable.

Export Mode: In the oscilloscope's menu, select USB Export. A new removable drive will appear on your computer.

Cleanup & Transfer: Delete all existing files on the oscilloscope's drive. Copy the new firmware file (must be named FSI-1014.bin) onto the empty drive.

Flash: Disconnect the USB cable and restart the device. The update should run automatically and take less than a minute. 2. Common Issues & Troubleshooting

Shifted/Misaligned Screen: This occurs because FNIRSI used two different screen types during production. If your screen shifts right or down after an update, you must re-flash with the alternative V3.0 version designed for your specific hardware.

"Bricked" Device / White Screen: If the device fails to boot, you may need to open the unit, remove the internal 8GB MicroSD card, and format it manually on a PC before re-installing the firmware.

File Corruption: Ensure you use a high-quality USB data cable; standard "charging-only" cables will not allow for the USB Export function to work. 3. Alternative & Custom Firmware

For advanced users, community projects like RAD Pro and other open-source versions on GitHub provide additional features or fixes not present in the factory software:

pecostm32 GitHub Repository: Includes a bootloader that allows you to switch between multiple firmware versions at startup by holding a button during power-on.

Custom Fixes: Some community versions improve RMS measurement accuracy and offer custom startup screens. FNIRSI 1014D - How to do a Firmaware Upgrade Tutorial

FNIRSI 1014D firmware update process involves manually transferring a

update file to the device's internal storage via a PC connection. The oscilloscope detects and installs this file automatically upon reboot. Update Procedure Follow these steps to update your device safely: Prepare the Firmware

: Download the latest firmware version (typically a file named FSI-1014.bin ) from the official FNIRSI Manuals & Firmware Connect to PC

Connect the FNIRSI 1014D to your computer using a standard USB data cable. On the oscilloscope, navigate to right arrow USB Export to enable data transfer mode. Transfer the File The process for updating the FNIRSI-1014D firmware involves

Your PC will recognize the device as a removable drive (often around 8GB). Crucial Step

: Some experts recommend cleaning existing files on this drive before copying the new one. FSI-1014.bin file directly to the root directory of this drive. Finalise Installation Eject/Unmount the drive from your PC and disconnect the USB cable. Power the oscilloscope and then back

The device will display a progress bar. Once finished, it will reboot automatically into the new firmware. Technical Tips & Troubleshooting Screen Alignment Issues

: If your screen appears shifted or off-center after an update, you may have used the wrong firmware variant. FNIRSI devices sometimes use different screens requiring specific versions; contact FNIRSI Support if this occurs. The "Vanishing" File : Do not be alarmed if the

file is missing when you reconnect the device to a PC after the update; the system automatically deletes the update file once the installation is successful. Custom Firmware

: For advanced users, open-source alternative firmwares are hosted on that provide additional features and bug fixes. for the latest stable version or a tutorial video for a specific hardware revision? FNIRSI 1014D - How to do a Firmaware Upgrade Tutorial 03-Jun-2021 —

The FNIRSI-1014D firmware update is a standard procedure for resolving system bugs, improving measurement accuracy, and fixing UI issues like screen misalignment. As of 2026, the most stable official release is Firmware V3.0. How to Perform the Firmware Update

The update process for the FNIRSI-1014D is straightforward but requires careful adherence to the following steps to avoid "bricking" the device:

Download the Firmware: Visit the official FNIRSI Support Page to find the latest .bin file (typically named FSI-1014.bin).

Connect to PC: Use a USB data cable to connect the oscilloscope to your computer.

Enable USB Export: Navigate to the oscilloscope's Menu and select USB export. Your PC should detect a new drive (approximately 8GB).

Clean the Drive: Remove any existing files from this drive to ensure a clean installation environment.

Transfer File: Copy the FSI-1014.bin file directly to the root of the oscilloscope's drive.

Safety First: Properly "eject" or "unmount" the drive from your PC before physically disconnecting the cable.

Initiate Update: Power the oscilloscope off and then back on. A horizontal progress bar should appear, completing the update in roughly 20 seconds. Troubleshooting Common Update Issues After the update

Screen Shift/Misalignment: If the display appears shifted to one side after updating, you likely have a different hardware version of the screen. FNIRSI released two variants of V3.0 to account for different display manufacturers. Re-updating with the alternative V3.0 file usually fixes this.

Failed Boot (Blank Screen): If the device fails to boot after an update, you may need to manually format the internal SD card. This requires opening the device, removing the card, and formatting it to FAT32 on a PC before reinstalling the firmware.

Persistent Measurement Errors: Some users report a 200mV difference between channels even after updating to V3.0. If this occurs, perform a manual calibration through the device settings without any probes connected. Custom and Community Firmware FNIRSI 1014D - How to do a Firmaware Upgrade Tutorial

Updating the FNIRSI 1014D firmware is a straightforward process that involves transferring a .bin file to the device's internal storage via a PC. However, users often encounter a "screen shift" issue due to the manufacturer using different display hardware across different production batches. Update Procedure

Download Firmware: Obtain the latest firmware (e.g., FSI-1014.bin) from the official FNIRSI support site or reputable community links if the official site is unresponsive.

Connect to PC: Use a USB-A to USB-A cable to connect the oscilloscope to your computer.

USB Export Mode: Navigate to MENU -> USB export on the oscilloscope. It should appear as a removable drive (typically 8GB) on your PC.

Transfer File: Delete any existing files on the oscilloscope's drive and copy the new FSI-1014.bin file onto it.

Initiate Update: Safely eject the drive and power the device off. Turn it back on; it should detect the file and show a progress bar for about 20 seconds before rebooting automatically. Critical Troubleshooting: The "Screen Shift" Problem

If your screen appears shifted or certain parameters are cut off after the update, you likely installed the version meant for a different hardware revision.

The Fix: Redo the update using the "other" version of the firmware. There are typically two versions of the V3.0 firmware to account for the two different screen types used in production.

Boot Failure: If the device fails to boot (backlight on but no image), you may need to remove the internal SD card, format it to FAT32 on a PC, and reload the correct firmware files directly. Community & Open Source Alternatives FNIRSI 1014D - How to do a Firmaware Upgrade Tutorial

I understand you're asking about performing a firmware update on the FNIRSI 1014D oscilloscope. Here’s a clear, practical answer based on common user experience with this device.

Q: Can the FNIRSI 1014D firmware update work via USB instead of SD card?

A: No. The 1014D lacks a DFU (Device Firmware Update) mode over USB. The SD card method is the only supported and reliable method.

Step 4: Enter Update Mode