Digi Sm5300b Manual Work Portable
DIGI SM-5300B is a PC-based bench-style weigh-labeller designed to bridge the gap between traditional manual scale operation and modern digital efficiency. When users refer to "manual work" with this device, they typically mean the hands-on processes of manual PLU entry label management clerk interactions DIGI (TERAOKA) Core Manual Operations Manual PLU Creation & Entry
: Operators can manually add new items by selecting a unique Price Look-Up (PLU) number directly on the touchscreen. This process involves: Entering the item name and cost. Setting the unit price by weight ( ) or per piece. Manually configuring secondary information
such as storage instructions (e.g., "Keep Frozen") and nutritional tables. Label Roll Replacement linerless labels
, which require manual loading into the green cassette. This design eliminates backing paper, allowing for more labels per roll and reducing the frequency of manual changes. Manual vs. Prepack Mode Manual Mode
: The operator selects a PLU, places the item on the load cell, and manually presses the print button to generate a ticket. Prepack Mode
: Designed for high-volume tasks, this mode automatically prints a label as soon as an item is placed on the scale, removing the need for manual button presses. Features to Reduce Manual Labor DIGI has integrated several features into the to minimize repetitive manual tasks:
: Uses RFID technology for "tap-to-login" clerk identification, removing the need to manually type in passwords. Hi-Touch Technology
: Compatible with electronic labels (InfoTags) that allow operators to "tap" a tag to instantly call up the correct PLU on the scale, preventing manual entry errors. Linerless Auto-Cutter
: A built-in cutter automatically adjusts to the size of the printed text, allowing one label roll to serve multiple product types without manual resizing. DIGI (TERAOKA) Technical Quick Specs DIGI (TERAOKA) Specification 7-inch WVGA Touchscreen Print Speed Up to 150mm/s (Liner) or 100mm/s (Linerless) 28 Preset Keys / 23 Alphanumeric Function Keys Connectivity Ethernet, 4 x USB 2.0, RJ11
Detailed documentation for these procedures can be found in the DIGI SM-5300 Service Manual or through official training videos like those on the DIGI System Global step-by-step guides for a particular task like changing label formats? Service Manual SM-5300: PC Scale Printer Edition 1 - Scribd
Operating the DIGI SM-5300B (Bench model) manually involves navigating its 7-inch WVGA color touch screen
to manage weighing, labeling, and product data. This PC-based scale is designed for high-traffic retail environments like markets and bulk-buy shops where flexibility is essential. DIGI (TERAOKA) Basic Weighing & Labeling Select an Item (PLU) Preset Keys
: Tap the programmed buttons on the left side of the operator screen. Manual Entry : Type the PLU number using the on-screen numeric keypad and press the Weigh the Product : Place the item on the load cell. Print Label Manual Mode : Press the button (bottom right) after the weight stabilizes. Prepack Mode : If enabled, the scale will automatically print
a label as soon as a stable weight is detected, allowing for faster processing of multiple items. Managing Product Data (PLU Programming) You can manually add or update items directly on the scale: Create New PLU : Enter the PLU Programming
, and type a unique number. If it doesn't exist, the system will prompt you to create it. Edit Fields : Use the touchscreen to fill in the Product Name Unit Price (per kg or piece), and (usually matching the PLU for POS compatibility). : Enter the Best-before
date by inputting the number of days from the current pack date. Ingredients & Messages
: Manually type ingredients or select "Special Messages" like "Keep Frozen" from a pre-defined list. Linerless Label Loading The SM-5300B often uses linerless labels with an auto-cutter to reduce waste. DIGI (TERAOKA) Open Cassette digi sm5300b manual work
: Push the green button/lever to the left to open the front door. Insert Roll : Place the label roll over the green bezel. Thread & Close
: Pull the paper through the "goal posts" (alignment guides) and close the door. Label Feed
icon (arrow pointing to a label) on the screen to align the paper for the first print. Key Features for Operators PC-Based Scales SM-5300B Case Studies BOB & ROY'S | DIGI
The DIGI SM-5300 is a PC-based weigh-labeller designed for retail environments, featuring high-speed printing and a user-friendly interface. This guide covers the essential manual operations for daily use. 1. Initial Setup & Powering On
Power Toggle: Locate the power switch (usually underneath or on the side of the base) and turn it on.
Initialization: Wait for the system to boot to the main registration screen. Ensure the scale platter is clear of any items during this process to allow for proper zero calibration. Zeroing: If the display does not show 0.0000.000 , press the [ZERO] key to reset the baseline weight. 2. Loading Labels
The SM-5300 often uses linerless labels with an auto-cutter feature to reduce waste . Open the printer cover (usually on the side of the unit). Remove the empty label roll core.
Insert a new roll, ensuring the thermal side (printable side) faces the print head. Feed the label edge through the auto-cutter and sensors.
Close the cover firmly; the scale should automatically detect the label size and align the paper . 3. Weighing & Labeling Operations
Manual PLU Entry: Type the PLU (Price Look-Up) number using the numeric keypad and press the [PLU] key.
Preset Keys: For high-volume items, use the touchscreen or physical preset keys to select a product instantly. Tare Weight Setup:
One-Touch Tare: Place an empty container on the scale and press [TARE]. The scale will subtract this weight from the total .
Digital Tare: If you know the weight of the container, type the value (e.g., ) and press [TARE] .
Printing: Once the weight stabilizes, the scale will automatically print the label (if in "Auto" mode) or wait for you to press the [PRINT] key. 4. Daily Maintenance
Print Head Cleaning: Use a thermal head cleaning pen or a soft cloth with isopropyl alcohol to wipe the print head daily to prevent streaks and maintain barcode readability.
Scale Platter: Remove and wipe down the stainless steel platter with a damp cloth to prevent debris buildup. Heavy terminals : Connect the main DC positive
Cutter Maintenance: Periodically check the auto-cutter for adhesive buildup, especially when using linerless labels. 5. Troubleshooting Common Issues
"Scale Not Stable": Ensure the scale is on a flat, vibration-free surface and that no fans are blowing directly on the platter.
"Paper Jam": Open the printer compartment and check for labels stuck to the rollers or cutter blade.
"No Label Detected": Ensure the label roll is seated correctly and that the paper sensor is not blocked by dust.
For detailed technical adjustments or network configurations, you can refer to the official SM-5300 Service Manual for deeper PC-scale printer settings .
The DIGI SM-5300B is a sophisticated PC-based bench scale designed to streamline retail operations through high-speed weighing and advanced labeling capabilities. Operating the unit effectively requires understanding its "manual work" functions—specifically how users interact with its touchscreen interface to manage inventory and facilitate customer transactions. The Role of Manual Operation in Retail Efficiency
Manual work on the SM-5300B primarily involves the direct handling of Product Lookups (PLUs) and label printing. Unlike automatic "pre-pack" modes that print continuously as items are detected, the manual mode is tailored for one-off items or service-counter interactions where a clerk must verify the weight or item before confirming the sale.
PLU Management: Operators manually program and call up items using a 7-inch WVGA color touch screen. Creating a new item involves assigning a unique PLU number, entering the product name (e.g., "fresh tuna"), and setting the unit price.
Preset Keys: To reduce manual data entry during rushes, frequently sold items can be assigned to 28 dedicated preset keys visible on the home screen.
Speed ID Technology: To improve accountability without the friction of manual password entry, the system supports near-field identification (NFI), allowing clerks to sign in with a simple tap. Technical Precision and Maintenance
Maintaining the scale’s accuracy is a critical part of the manual workload. The SM-5300B is a multi-interval instrument, meaning its precision shifts based on the load: it offers a verification scale interval of 0.002 kg up to 6 kg, and 0.005 kg up to its 15 kg maximum capacity.
Manual maintenance tasks often focus on the printing system:
Label Loading: Operators must manually replace label rolls, which can include traditional liner labels or eco-friendly linerless labels.
Auto-Cutter Maintenance: The scale features a built-in auto-cutter for linerless rolls, which requires periodic checking to ensure smooth operation and minimal downtime.
Environmental Resilience: Because the unit is often used in fresh-food environments, it is designed to operate in temperatures ranging from -10°C to +40°C. Enhancing the Customer Experience
The manual work of the operator is supported by the scale's interactive features. While the clerk works on the operator-facing screen, a customer-facing 7-inch display can show advertisements, promotional text, or receipt details to engage the buyer. This dual-display system ensures that the manual task of weighing and labeling also serves as a point-of-sale marketing opportunity. Switch SW1 (example):
By combining manual touchscreen controls with automated features like the auto-cutter and Speed ID, the DIGI SM-5300B minimizes the labor required for complex retail weighing tasks while maintaining the high reliability needed for high-traffic environments. SM-5300 | Retail | DIGI America
To view or print reports on a DIGI SM-5300B scale, you can access the report menu directly through the touchscreen interface. How to Access Reports
Open the Menu: Tap the secondary option button on the 10.1-inch touch screen. Select Report Type: From the menu, you can choose:
Closing Report: For a summary of printed items at the end of a shift or day.
Printed Items & Quantities Report: For a detailed breakdown of specific PLU (Price Look-Up) movements.
Remote Access: If your scale is connected to the @LABEL management application, sales reports are automatically collected in a central location for remote analysis. Key Manual Details
Operating Modes: The scale supports Manual Mode (pressing a button to print) and Prepack Mode (automatic printing when an item is placed on the load cell).
Technical Support: You can find the full Service Manual on Scribd, which covers technical maintenance and printer setup.
Support Contacts: For specific troubleshooting, DIGI Singapore provides service support on weekdays and weekends. SM-5300 | Retail | DIGI America
Based on the typical functionality of the Digi SM 5300B (a high-performance retail scale with label printing capabilities), I have designed a comprehensive software feature guide for "Manual Work" operations.
In the context of this device, "Manual Work" usually refers to Manual Weight Entry (for non-weighable items), Manual Label Printing, or accessing Manual Override Functions without using the primary PLU database.
Here is a Feature Specification for the Manual Work Module.
3. Functional Requirements
Digi SM5300B: Locating the Manual and Basic Operational Guide
Q3: Why does my scale show "Err 5"?
This often indicates a manual entry error during calibration or tare. Restart and repeat the process carefully.
3.1. Shunt Connection
The SM5300B works with an external shunt (included or purchased separately).
- Heavy terminals: Connect the main DC positive (+) line to one side of the shunt, and the load/charger to the other side.
- Sense wires (thin): Connect S+ (shunt positive) and S- (shunt negative) to the SM5300B terminals labeled “Shunt In”. Polarity is critical – reversing these will give negative current readings.
Calibration Steps
- Turn off the scale.
- Press and hold the
TAREkey, then pressON/OFFwhile holding Tare. - Release both when you see a code prompt (e.g.,
CALorPASS). - Enter your calibration code using the numeric pad. Press
ENTER. - The display will show
Unload. Remove all weight from the platform. PressENTER. - The display will show
Loadand a target weight value. - Place your known calibration weight on the platform.
- Use the number keys to adjust the displayed value to match the weight (e.g., enter
10.000for 10 kg). - Press
ENTER. The display will showPASSorEND. - Turn the scale off and on again.
Verify: Place the calibration weight back on. The display should match exactly.
2.4. Firmware & Boot Configuration (Physical Jumpers/Switches)
The manual documents manual work for boot source selection via physical switches on the carrier board (not on the module itself):
- Switch SW1 (example):
- Position 1-2: Boot from SD card (for manual firmware recovery)
- Position 2-3: Boot from internal eMMC (normal operation)
- Manual Work Step: Change switches only when the module is completely powered off (all LEDs dark).
3.3. Auxiliary Power (If Required)
Some versions need separate 12-24V DC auxiliary power to power the display when battery voltage is too low. Connect to AUX+ and AUX-.