Autokent Mvci Multi Driver X64 Install ›
Here’s a step-by-step guide for installing the AutoKent MVCI Multi-Driver (x64) on a Windows 64-bit system.
This driver is commonly used with MVCI (Multi-Vehicle Communication Interface) J2534 diagnostic tools for vehicles like Toyota, Lexus, Scion, etc.
Phase 2: Firmware Flashing (The "Multi" Part)
The “multi” capability requires specific firmware. Many sellers ship units with Toyota-only firmware.
- Run the
MVCI_FirmwareUpdater_x64.exe(included with the multi-driver pack). - Select the
Multi-J2534.binfile. - Click
Flash. The LED on the MVCI will flicker red/green. - Once complete (about 10 seconds), unplug the MVCI and plug it back in.
To verify: Open the MVCI_Config_Tool.exe. Under “Device Info,” you should see:
- Firmware Version: 1.4.6 or higher
- Protocol: J2534-2 Multi
Option B – Temporary (one boot)
- Hold
Shift+ click Restart - Troubleshoot → Advanced Options → Startup Settings → Restart
- Press
7orF7for “Disable driver signature enforcement”
Option B: Manual USB driver install (if no setup.exe)
- Extract ZIP to a folder (e.g.,
C:\Drivers\AutoKent). - Plug in the MVCI device via USB.
- Open Device Manager → find “Unknown device” or “MVCI” with yellow mark.
- Right-click → Update driver → Browse my computer → point to the extracted folder.
- Select Include subfolders → Next.
- Confirm installation of “J2534 Pass-Thru” driver.
🔐 Security & Legal Note
- These drivers are often unsigned and may contain code from third-party developers. Use only in an isolated diagnostic environment (not on a daily-use PC).
- Ensure you have the legal right to use the MVCI hardware and associated OEM software.
Final check: After install, restart your PC once more before launching any diagnostic application. If the device still fails, test on a clean Windows 10 LTSC or Windows 7 x64 (most compatible).
Autokent MVCI Multi-Driver x64 is a specialized driver package designed to enable Mini VCI J2534
cables to function on 64-bit Windows systems (Windows 7, 8.1, 10, and 11). It is primarily used with Toyota Techstream software for vehicle diagnostics. Key Features and Compatibility autokent mvci multi driver x64 install
: Overcomes the limitation where standard MVCI drivers only support 32-bit systems. Software Support : Specifically designed for use with Toyota Techstream to diagnose Toyota, Lexus, and Scion vehicles. Multi-Version Selection
: Allows users to select different driver versions (e.g., 1.4.8) within the Techstream interface. Vehicle Compatibility
: While widely used for Toyota, it has limited or unreliable support for other brands like Ford (via FORScan) due to hardware limitations. Installation Steps for x64 Systems Manual installation is often required as the standard installers frequently fail on 64-bit architecture. Prepare Driver Files Extract the contents of the MVCI Driver for TOYOTA.msi file manually using tools like or via a command line extract:
msiexec /a "C:\temp\MVCI Driver.msi" /qb TARGETDIR=c:\temp\mvci Relocate Driver Folder Create the directory
C:\Program Files (x86)\XHorse Electronics\MVCI Driver for TOYOTA TIS Move the extracted files into this new folder. Manual Driver Update Connect the Mini VCI cable to your USB port. Device Manager Here’s a step-by-step guide for installing the AutoKent
. Locate the failing devices (often labeled as "M-VCI" or "USB Serial Port") with yellow warning icons. Right-click each and select Update Driver Browse my computer and point to the folder created in Step 2. Registry Modification Run the provided file (often named mvci-x64.reg ) to register the driver as a device in the Windows Registry. Verify that the FunctionLibrary path in the registry points correctly to MVCI32.dll in your installation folder. VIM Selection Techstream VIM Selection and select MVCI Autokent-X64 XHorse - MVCI from the dropdown menu. Troubleshooting Common Issues Connection Errors : Ensure the
for the USB Serial Port is set correctly in Device Manager (often Port #4). Firmware Verification FirmwareUpdateTool.exe
within the driver folder to check if the cable is recognized by the driver, but
attempt to update the firmware, as this can brick some clone cables. Antivirus Interference
: Some tools like the firmware checker may be flagged by antivirus software; temporary disabling or adding exclusions may be necessary. to download the specific x64 registry patch for your version? Techstream and MVCI on 64bit Windows 8.1 works! Phase 2: Firmware Flashing (The "Multi" Part) The
Guide: Installing AutoKent MVCI Multi-Driver (x64)
Applies to: Windows 7, 8, 10, 11 (64-bit)
Device: AutoKent MVCI (J2534 / DoIP / CAN)
Goal: Successfully install the multi-driver for diagnostic software compatibility.
⚠️ Important Pre-Installation Steps
-
Disable Driver Signature Enforcement (Windows 8/10/11)
- Restart PC → Hold
Shiftwhile clicking Restart → Troubleshoot → Advanced Options → Startup Settings → Restart → Press7(Disable driver signature enforcement). - Why? AutoKent drivers are often not Microsoft-signed.
- Restart PC → Hold
-
Uninstall old drivers
- Go to
Control Panel → Programs and Features→ Remove any previous “MVCI”, “J2534”, or “AutoKent” drivers.
- Go to
-
Turn off antivirus temporarily (false positives on driver files).
-
Connect the device – Do not plug in the MVCI until step 5.