Atlas Copco Elektronikon Mk5 Wiring Diagram Full Verified [360p]

For a full wiring diagram of the Atlas Copco Elektronikon Mk5, the most reliable official source is the 9828450599 Electrical Drawing

. This 11-page document covers the entire electrical layout, including power circuits for the main motor and dryer, supply control circuits, and specific regulator diagrams for both Graphic and Touch versions. acprodbponlinebcc5.blob.core.windows.net Key Wiring Sections

The full diagram is typically organized into specialized sheets: acprodbponlinebcc5.blob.core.windows.net Power Circuit (Main Motor & Dryer):

Details the high-voltage supply, motor data (e.g., kW, HP, SF), and fuse settings. Regulator Mk5 (Graphic & Touch):

Pinouts and connection points specifically for the Mk5 controller unit. Input Connections:

Standard 2X27 or 3X33/3X34 terminal blocks for various sensors and switches. Control Circuits: Solenoids and internal component control logic. Optional Components:

Wiring for smartboxes, phase sequence relays (K25), and electronic water drains (B1). acprodbponlinebcc5.blob.core.windows.net Reference Resources

If you need specific diagrams for different compressor models or gateway setups, these technical documents provide detailed schematics: GA18-30 VSD+ Service Diagram: Includes a detailed Electrical Service Diagram for Mk5S variants. EKO75-kW VST Diagram: Provides a 75kW Variable Speed Motor diagram with full MK5 control circuit details. Gateway Module Guide: For networking and remote control, the Mk5 Gateway Manual outlines Modbus and Profibus pin-layouts. General Wiring Guide: Elektronikon Wiring Guide covers equipment components and display menus.

Elektronikon MK5 Wiring Diagram | PDF | Electrical Components

The Atlas Copco Elektronikon Mk5 is the current generation of compressor controllers, featuring advanced monitoring, energy-saving algorithms, and integrated connectivity via Smartlink, Modbus, and Profibus. A full wiring diagram for this system typically spans multiple sheets, covering main power supply, control circuits, and sensor inputs. Core Wiring Components

A complete Mk5 electrical diagram (such as for a 75kW VSD unit) is structured as follows:

Sheet 1: Index & Legends: Explains all symbols and provides an overview of the document structure.

Sheet 2–3: Power Circuit: Details for the main motor (M1) and dryer circuits (A1), including max fuse ratings (IEC gL/gG or UL Class CC).

Sheet 4: Supply Control Circuit: Shows the 24VDC power supply and main isolation switch (S10).

Sheet 6–7: Regulator Terminals: Pin-out connections for either the Mk5 Graphic or the Mk5 Touch controller.

Sheet 8–11: Input/Output Connections: Specific wiring for digital and analog inputs (e.g., pressure sensors, temperature sensors TT53/TT54). Input/Output Specifications

The Elektronikon Mk5 comes in two primary versions with varying I/O capacities: Mk5 Standard (Graphic) Digital Inputs Analog Inputs Digital Outputs Connectivity CAN, RS485 Ethernet, USB, CANopen Helpful Technical Review Elektronikon Mk5 Modbus/Profibus Guide | PDF - Scribd

The Atlas Copco Elektronikon Mk5 is a comprehensive compressor controller featuring a full-color graphic display, advanced energy-saving algorithms, and integrated connectivity via SMARTLINK. Its electrical wiring is organized into several distinct circuits, typically spanning 10 or more detailed service sheets. Core Wiring Components

A full Mk5 wiring diagram typically includes the following major sections:

Power Circuit (Main Motor & Dryer): Detailed schematics for the main motor supply, including dryer settings and fuse requirements (e.g., IEC aR or UL Class T). atlas copco elektronikon mk5 wiring diagram full

Supply Control Circuit: Covers the primary 24VDC supply and transformer connections that power the controller itself.

Regulator Terminals (Mk5 Graphic/Touch): The physical connection points for the controller’s main unit, including grounding (earthing) requirements. Input/Output Connections:

Analog Inputs: Typically supports 7–10 inputs for pressure and temperature sensors.

Digital Inputs: Includes 4–10 inputs for remote start/stop, emergency stops, and alarm resets.

Digital Outputs: Features 6–9 relay outputs for solenoid valves and status signaling. Full Feature List (Mk5 vs. Legacy)

The "Long Feature" Mk5 offers significant technical upgrades over older MK1–MK4 models:

GA18 - 30 - VSDplus - Electrical - Service - Diagram - Mk5S - Antwerp

The wiring diagram for an Atlas Copco Elektronikon Mk5 controller generally spans multiple schematic sheets, covering everything from the main power supply to specific digital and analog input/output (I/O) connections.

While specific terminal numbers can vary based on your machine's model (e.g., GA series vs. Scroll) and power rating, the following breakdown represents the standard full-text architecture found in official service diagrams. 1. Power and Supply Circuits

Main Power Supply: Connects to the primary voltage (e.g., 380V-460V) with dedicated grounding and short-circuit protection via IEC gL/gG or UL Class CC/T fuses.

Control Supply (24VAC/DC): The Mk5 module typically requires a 24VAC / 16VA supply.

Phase Sequence Relay (K25): An optional component often integrated into the power circuit to protect the motor from reverse rotation. 2. Controller I/O Terminals

The Mk5 Graphic and Touch units typically feature a set number of inputs and outputs: GA18 - 30 - VSDplus - Electrical - Service - Diagram - Mk5S

The Atlas Copco Elektronikon Mk5 (Mark V) is a sophisticated controller used across a wide range of Atlas Copco industrial air compressors, including the GA, Z, and VSD series. Understanding its full wiring diagram is essential for installation, troubleshooting, and integrating the compressor into a plant management system. Core Wiring Layout of the Elektronikon Mk5

The wiring for the Mk5 is generally divided into several primary circuits:

Main Power Supply: Connects the compressor to the plant's electrical grid. Common voltages include 380V, 400V, or 460V at 50/60Hz.

Main Motor Circuit: Controls the primary motor (M1) and includes protection components like fuses (e.g., IEC gL/gG or UL Class CC) and phase sequence relays (K25).

Control Supply Circuit: Often uses a 24VDC supply (U2) to power the Elektronikon module and associated sensors.

Integrated Dryer Circuit: For models with an integrated refrigerant dryer, this separate circuit controls the dryer motor and solenoid valves (Y2). Key Input and Output Connections For a full wiring diagram of the Atlas

The Elektronikon Mk5 typically features a standard set of I/O terminals for machine monitoring and control: Connection Type Standard Count Common Uses Digital Inputs

Emergency stops, remote start/stop, and load/unload commands. Analog Inputs

Pressure transducers (outlet pressure) and temperature sensors (element outlet). Digital Outputs

Relays for the main contactor, star-delta starters, and alarm beacons. Advanced Connectivity: CAN, Modbus, and Profibus The Mk5 is designed for modern industrial networks:

Atlas Copco Elektronikon Mk5 Manual - sciphilconf.berkeley.edu

The Atlas Copco Elektronikon Mk5 is the central control unit for modern industrial air compressors, serving as the "brain" that manages motor operation, energy efficiency, and system diagnostics. A full wiring diagram for this controller typically encompasses the main power supply, control circuits, and a specific array of input/output (I/O) connections tailored to the compressor model. Core Wiring Components

Official service diagrams for the Mk5 system are structured into several critical sheets:

Main Power Supply: Maps the incoming voltage and frequency requirements.

Motor Data & Power Circuit: Details the wiring for the main motor (M1) and, if applicable, the integrated dryer.

Control Circuit Supply: Outlines the low-voltage power path to the regulator itself.

Regulator Connections: Specific pinouts for the Mk5 Graphic or Mk5 Touch interfaces. Input and Output (I/O) Specifications

The Elektronikon Mk5 features a robust set of connections to monitor and control the compressor's environment:

Digital Inputs: Typically 4 to 10 inputs for monitoring discrete states like emergency stops or pressure switches.

Analog Inputs: Typically 4 to 7 inputs for continuous data like temperature and pressure sensors.

Digital Outputs: Usually 6 to 9 outputs to trigger contactors, solenoid valves, or alarms.

Connectivity Slots: Includes dedicated ports for Ethernet, CAN, and sometimes an SD card slot for data logging or firmware upgrades. Communication and Networking

For advanced system integration, the Mk5 supports industrial protocols:

Modbus & Profibus: Integration requires a specific gateway module inserted into the CAN-based network, allowing the compressor to act as a proxy with its own unique address.

Remote Monitoring: Connectivity via Smartlink or Ethernet allows for real-time trending and predictive maintenance. Installation and Safety Guidelines Group A: Mains Supply & Digital Inputs

Grounding: A low-resistance connection (maximum 20cm wire length) must be made between the controller’s earth terminal and the enclosure chassis. Use M4 eye-terminals or FASTON receptacles for shielding and grounding.

Protection: The system must be earthed and protected by fuses in all phases, with a lockable power isolating switch nearby.

Official Documentation: For exact pinouts related to your specific serial number, consult the Atlas Copco Instruction Books or professional engineering resources like Scribd.

Are you troubleshooting a specific error code on the Mk5, or do you need the pinouts for a Modbus integration?

Atlas Copco Elektronikon Mk5 Manual - sciphilconf.berkeley.edu

The Atlas Copco Elektronikon Mk5 is a sophisticated industrial controller used across various compressor models, including the GA and Scroll series. Due to the variety of machine configurations (fixed speed, VSD, integrated dryers), there is no single "universal" diagram; instead, the system utilizes a modular electrical architecture. Core Wiring Components

Typical Mk5 electrical diagrams are organized into functional sheets to simplify troubleshooting and installation:

Main Power Circuit: Details the 3-phase supply, main motor (M1) specifications, and primary fuses (typically gL/gG or UL Class CC).

Control Supply: Shows the transformer and protection for the control voltage (e.g., 230V for IEC or 115V for CSA/UL standards).

Regulator (Mk5 Graphic/Touch): Maps the physical pins of the controller unit, including power input and communication ports. Input/Output Connections: Specific terminal maps for:

Analog/Digital Inputs: Pressure sensors, temperature probes (ADT), and emergency stops.

Relay Outputs: Loading/unloading solenoids, motor starters, and general alarms. Communication & Networking

The Mk5 supports advanced networking via a CAN-based internal network. For external integration, a Gateway Module is often used:

Modbus/Profibus: Requires a specific bridge module that acts as a proxy for the compressors on the network.

Remote Control: Terminals for remote start/stop and load/unload are typically located on the customer terminal strip. Critical Safety & Technical References Technical Detail Control Logic Regulates pressure bands and motor speed (VSD). Scribd - Elektronikon Mk5 Manual Wiring Guide iPCB connection drawings for various compressor models. Scribd - Wiring Guide Service Diagram Detailed layout for 75kW VSD systems. Scribd - Service Diagram Gateway Setup Instructions for Modbus and Profibus configuration. Emerson Exchange 365 - Gateway Manual Atlas Copco GA90-315 Electrical Diagram | PDF - Scribd


Group A: Mains Supply & Digital Inputs

Section C: The MK5 Signal Connector (X2 – 37-pin D-sub)

This is the "Rosetta Stone" of the diagram.

| Pin Group | Typical Function | Wire Color (Standard) | Common Fault | | :--- | :--- | :--- | :--- | | 1-2 | PT1000 (Temperature sensor - Element) | Red/White | Open circuit (displays -40°C) | | 3-4 | PT1000 (Return) | White/Red | Short circuit (displays >200°C) | | 5 | Analog Input 0-10V (Pressure) | Yellow | Ground loop drift | | 6 | +10V Reference for pressure sensor | Green | Blown (causes zero pressure reading) | | 13-14 | Remote Start/Stop (Dry contact) | Blue/Blue | Corrosion in external switch | | 18 | RS-485 (A) | White/Yellow | Communication timeout | | 19 | RS-485 (B) | Yellow/White | Incorrect termination resistor | | 22 | Digital Input: Emergency Stop status | Orange | Worn E-stop contact | | 30 | Digital Ground (0V DC) | Black | Missing reference for all inputs |

Part 5: Three Common Scenarios Solved Using the Full Wiring Diagram

Let’s apply the diagram to real-world repairs.

Section A: Power Supply Incoming (L1, L2, L3)